150
Turn the locking knob, and open the exterior water heater
panel to the open position (photo ).
To open the panel to the (or service) position, the
door must rst be open as shown in (). Then lift the door
so it comes out of the slots along the bottom of the door
(photo ).
Lower the door so it lays at against the RV hanging down
by the straps (photo ).
To close the door, insert the tabs back into the slots at the
bottom of the door, close the panel and rotate the locking
knob. Make sure the straps are not pinched between the
door and the cover plate.
Close the water heater bypass lines (if so equipped).
Turn on the fresh water supply or switch on the water
pump.
Fill the plumbing system. Open all faucets, showers, toi-
let to bleed air from the lines.
When water begins to ow out of the faucets, the system
is vented.
Close all xtures.
Make sure the LP gas supply is turned ON.
Turn on the 12VDC power in the RV.
Open the water heater access door (as explained previ-
ously).
Turn the power switch on by selecting either ECO or
COMFORT position. The green LED (1) will light at
the top of the power switch.
If the RED LED () below the switch lights or ashes,
it indicates an error condition. Refer to the appliance
owner manual for error codes.
Inspect your water heater monthly and have it serviced at least once a year by the manu-
facturer’s recommended service technician. Contact your RV dealer, the manufacturer or
Customer Service.
The Aqua Go water heater will have the ECO/
COMFORT settings. It only has a basic power switch.
If the vehicle is standing and
ambient temperatures are below -4°F (-20°C) the appliance must be
operated and be winterized.