The following information details the functions of the utility center water valves as dis-
played on the valve operation label:

1. Connect the fresh water hose to the City water connection inlet on the utility center.
2. Set the color coded valves to POWER FILL TANK setting:
(A) White handle pointing right
(B) Blue handle pointing left
(C) Black handle pointing right
(D) Red handle pointing up
(E) Green handle pointing right
3. Connect the other end of the hose to a pressurized fresh water source (faucet or spigot).
4. Turn the pressurized water source ON, the tank should begin lling.
5. When water has reached the desired level, turn the pressurized water source OFF.
6. Disconnect water source from the spigot/faucet rst, then disconnect from the city wa-
ter ll inlet on the utility center. 

1. Connect a garden hose to the city water inlet (do not use your fresh water hose to sani-
tize the water lines or the tank).
2. Set the colored coded valves to the SANITIZE setting:
(A) White handle pointing down
(B) Blue handle pointing down
(C) Black handle pointing right
(D) Red handle pointing left
(E) Green handle pointing right
The water heater is automatically bypassed on this setting.
A check valve is located inside the city water connection inlet on the utility
center.        
 It will cause irreparable damage to the
valve function and the inlet will leak water.

 Refer to the Sanitizing Plumbing System section before starting
this process.