41
5. Operation and maintenance devices
Once the window "Parked regeneration required", the feeder also stops. With "OK" you
get to the next menu and with "Yes" the regeneration process can be initiated. If the
regeneration process is rejected with "No", the machine can be used for another 120
minutes before the machine finally stops and the regeneration process has to be
initiated at a standstill. If the regeneration process is confirmed with "Yes", you will be
taken to the following menu sequence.
If high exhaust gas temperatures are to be expected during the regeneration process,
the corresponding symbol is also displayed on the display. In addition, it is pointed out
that during regeneration the feeder cannot be activated and therefore it is not possible
to work with the machine. If this menu is confirmed with "OK", you will be taken back
to the start menu.
Figure 9Request parked regeneration
Figure 10: Menu sequence for initiating parked regeneration