5.2.4 Settings
Once the unit has been turned ON the type of default
wheel is displayed.
Status at switching on
The electronic unit is factory-adjusted to the following
modes of operation, which are available after switching
on:
- wheel type 1 (car wheel with nominal dimensions in
inches, width 6.5” and diameter 15.0”).
- entry of rim data in inches.
- display of amount of unbalance in 5-g increments.
- suppression of minor unbalance readings (limit set to
3.5 g).
- automatic braking of wheel when guard is opened
during the measuring run.
- compensation of adapter unbalance switched off start
of measuring run by START key only.