5.3 IN THE FIELD REPROGRAMMING OF BALANCER
After software down loading, perform service codes in the following order:C47 - Select machine model: after the
selection, the machine will make three audible beeps followed by the automatic turning o! and on again.
C80 - Calibration of inner SAPE gauge arm
C81 - Measurement of " ange to zero plane distance
C83 - Basic calibration of vibratory system with wheel
C84 - Measurement of residual main shaft unbalance
C88 - Adjustment of 12h position
C115 Basic calibration of vibratory system with calibration rotor
The machine is now ready for use.
5.4 RECOMMENDED SERVICE STEPS
In case of an error it is recommended to perform some service code to check the system. The following are some
common service codes for this job.
C28 - Indicate the content of the error record
C54 - Some more testing for the incremental encoder of the main shaft
C55 - Check lines Voltage
C56 - Check the pedal switches. The switches and the Function-Code to lock the power clamp should be
checked if the power clamp does not work
C63 - Continuous measurements for test of valid results.
C67 - Indicate the phase stability/shift of the vibratory system
C71 - Display angular deviation of the vibratory system as measured with C code 115.
C72 - Measure the angular deviation of the vibratory system
C74 - Check the incremental encoder of the main shaft
C75 - Check Voltages of SAPE potentiometers (AD8, AD9, AD10) or perform STEP 1 of C80 and C82
C80 - Check Voltages for left SAPE
ATTENTION! This is a calibration function; interrupt this function after the test in STEP 1 with the RETURN key
C81 - Check Voltages for right SAPE
ATTENTION! This is a calibration function; interrupt this function after the test in STEP 1 with the RETURN key
C92 - Test of o! -set and diameter potentiometers
C103 - Test of transpindence and unbalance signal ampli# ers.
C104 - Test of transducers.
C110 - Check VCC Voltage
5.5 SELFTEST DURING STARTUP
A series of tests is accomplished after the machine has been turned on. If a test is not successful:
A series of audible signals is given
An error code is read out.
A three-tone signal is given once if the machine is operative.
In case there is a functional error it must be acknowledged by pressing the STOP key and there is no three-tone
signal.