42
E300 Check availability of keyboard
Code C28
Complaint
Turning the machine on the display shows E300. It is not possible to access to any display
information.
Root cause
The balancers devices, such Optoencoder, HUB board and Keypad, communicate each other
through the communication bus I2C.
If one or more devices will not work or communicate, the communication bus I2C detects a
problem showing E300.
Service Code
Actions to do
Check stop cable
Check optoencoder main shaft and the cable
Check the interface Integrated Dispaly cable.
Defective nterface Integrated Display.
Check the weight laser board cable
Defective weight laser board
E341 Check sum of EEPROM 2 is wrong
Code C28
Complaint Turning the machine on the display shows E341.
Root cause Contents of EEprom 2, optoencoder, is di! erent because defective or replacement
Service Code C47, C85
Actions to do
Make sure about the proper communication with C74.
Check the " at cable from Optoencoder.
Make sure that the there si not " uctution of power supply during balancer booting
Perform the C85 if Optoencoder has been replaced
E623 Virtual dimensions wrong
Code C28 620530
Complaint During the C115 the balancer shows E623
Root cause The Integrated Dispaly has encountered a reversed signal from one or both transducers
Service Code C115, C84, C88.
Actions to do
Check the transducers wiring.
Perform the C codes above reported.
E900 Check model information
Code C28
Complaint Turning the balancer on the display shows E900.
Root cause The stored machine model is not known.
Service Code C47, C86, C80, C81, C115, C84, C88,
Actions to do
Perform C47 and select the proper model.
Check the Integrated Display.
E901 Check calibration
Code C28
Complaint Turning the balancer on the display shows E901.
Root cause Machine was not calibrated
Service Code C80, C81, C82, C115, C84, C88, C122
Actions to do Perform the calibration as above