SAB 193-233-283 S A-frame (including ATEX)
Screw compressor units
Engineering manual
en

Table of Contents

Questions and Answers

  • F
    Frederick JonesAug 21, 2025
    How to troubleshoot a Johnson Controls Air Compressor that won't start?
    • J
      John HodgesAug 21, 2025
      If your Johnson Controls Air Compressor won't start, check the main switch and fuses, and reset the emergency stop switch. Also, check for any alarms in the control system and reset if necessary. Finally, ensure the oil level is sufficient and charge oil if needed.
  • T
    Taylor HughesSep 4, 2025
    Why does my Johnson Controls Frick SGC 1913 start and then stop immediately?
    • B
      Benjamin PittsSep 5, 2025
      If your Johnson Controls Air Compressor starts but stops immediately, it could be due to an oil system failure related to temperature, pressure, or level. Check the oil level and the valve positions.
  • A
    Audrey ThomasSep 3, 2025
    What causes high oil filter differential pressure in Johnson Controls Air Compressor?
    • A
      anthonymartinSep 3, 2025
      High oil filter differential pressure in your Johnson Controls Air Compressor is likely due to a clogged oil filter. Replace the oil filter to resolve this issue.
  • C
    carla84Sep 1, 2025
    What to do if the Johnson Controls Air Compressor pump doesn't produce enough oil pressure?
    • W
      whitneyfisherSep 1, 2025
      If the pump on your Johnson Controls Air Compressor isn't producing enough oil pressure to start the compressor, check the pump rotation. Ensure the service valves are open. Inspect the filter cartridges for blockages by checking the pressure difference across the filters. Also, check the strainer for blockages and clean it if necessary. Verify that the oil pressure regulator is not set too low or stuck open, and readjust or repair it. If the pump is worn out, repair or replace it. Finally, check if the hand expansion valve may be opened too much and throttle the valve.
  • S
    Scott RobinsonAug 31, 2025
    What causes high suction pressure and insufficient refrigeration capacity in a Johnson Controls Frick SGC 1913 Air Compressor?
    • J
      Janet HuntAug 31, 2025
      High suction pressure combined with insufficient refrigeration capacity in your Johnson Controls Air Compressor can occur if the compressor protection valve is opening or leaking, so check the discharge pressure safety cut-out settings and the pilot/main protection valve. An oil return valve that is fully open can also cause this issue, so adjust the regulating valve. Finally, a clogged suction strainer can lead to these symptoms, so clean the strainer.
  • B
    brett66Aug 29, 2025
    Why won't the capacity slide valve move on my Johnson Controls Air Compressor?
    • C
      Catherine WhiteAug 29, 2025
      If the capacity slide valve or slide stop on your Johnson Controls Air Compressor won't move, preventing unloading/loading, it could be due to insufficient oil pressure, so check the oil pressure. The solenoid coils might be burned out, requiring replacement. Incorrect valve settings in the hydraulic system could also be the cause, so check according to the hydraulic system description. Lastly, a malfunction of the 4-way control valve of slide components could be the issue, so check according to the description of main components.
  • I
    igarciaAug 26, 2025
    What to do if my Johnson Controls Frick SGC 1913 Air Compressor has excessive noise and vibration?
    • S
      Stephanie MartinezAug 27, 2025
      Excessive noise and vibration in your Johnson Controls Air Compressor could stem from several issues. The main oil injection valve may be closed or open too far, so open or adjust it accordingly. Bearing damage or excessive wear can also cause this, requiring bearing replacement. Additionally, the slide valve/slide stop might be out of calibration, needing calibration. A loose coupling on the shaft should be tightened or replaced if damaged. Finally, refrigerant flood back (liquid slugging) can lead to these symptoms, so correct the underlying system problem.
  • L
    Lisa Hurst PhDAug 25, 2025
    How to fix excessively low suction pressure in Johnson Controls Air Compressor?
    • M
      Michael BlackburnAug 26, 2025
      Excessively low suction pressure in your Johnson Controls Air Compressor can be caused by a refrigeration load that's lower than the compressor capacity; in this case, reduce compressor capacity. It could also be due to high suction line loss, so check the valves and strainers. Another cause might be a malfunction of the evaporator, so inspect the evaporator for fouling or accumulated oil. Also, check the liquid expansion valve system, filter in the liquid line, and ensure there is sufficient refrigerant charge.
  • L
    Lauren OrtegaAug 23, 2025
    Why is the discharge pressure excessively high in my Johnson Controls Frick SGC 1913?
    • G
      Gerald PattersonAug 23, 2025
      Excessively high discharge pressure in your Johnson Controls Air Compressor can be due to several reasons. The safety cut-out might be set too low, so check the settings of alarms and warnings. There could be high discharge line loss, so inspect the valves. A malfunctioning condenser may also be the cause; check the condenser, liquid drain, refrigerant charge, water/air inlet temperature, and water/air flow. Finally, air or non-condensable gasses in the system can cause this issue, so purge the air from the condenser side.

Summary

1. Introduction

1.1 Purpose

Provides data for sales, planning phases, component descriptions, technical functions, refrigerant safety, connecting data, and installation.

1.2 Main users

Intended for sales, service, and contracting purposes; maintenance by competent personnel.

1.3 Compressor name, Sabroe;Frick

Explains how Sabroe and Frick compressor names are made up and correspond.

1.4 Amendments to the manual

Lists changes and revisions made to the manual across different versions.

1.5 Manufacturers information

Provides contact details and copyright information for Johnson Controls Denmark ApS.

1.6 Safety precaution definitions used in this manual

Defines safety terms like Danger, Warning, Caution, and Note.

1.7 Requirements for competent persons

Specifies qualifications and training required for personnel working on the unit.

2. Signs and warnings

2.1 Main users

Information on signs and warnings is intended for all users.

2.2 Identification of Johnson Controls Denmark equipment

Describes how to identify equipment via name plates.

2.3 Compressor name plate

Details the information contained on the compressor name plate.

2.4 Compressor name plate - ATEX

Explains the ATEX compressor name plate details.

2.5 Labelling of explosion-proof equipment

Describes ATEX labelling, material groups, categories, hazardous environments, and temperature classes.

2.6 Vessel name plate

Details the information found on the pressure vessel name plate.

2.7 Unit;pipe system name plate

Describes the information on the unit and pipe system name plates.

2.8 Signs

Illustrates and explains various signs found on the equipment.

3. Safety precautions

3.1 Areas of application

Defines the correct usage and limitations for the screw compressor.

3.2.1 General precautions

Provides general safety guidelines and requirements for operation and maintenance.

3.2.4 Safety during maintenance and service

Outlines safety measures to be followed during maintenance and servicing activities.

3.2.7 Lubricating oils

Details the types of lubricating oils and safety instructions for handling.

3.2.11 First aid for accidents with ammonia

Provides first aid measures for ammonia exposure.

4. Technical description

4.1 Description of the screw compressor

Describes the screw compressor unit's design, construction, and features.

4.3 Description of main components and systems

Lists and briefly describes the major subsystems of the screw compressor unit.

4.4 Control system

Details the UniSAB III control system, its functions, and capabilities.

4.5 Compressor

Describes the compressor's design, including suction strainer and stop valve.

4.12 Compressor oil separation system

Explains the oil separation system, its design, and operating mode.

4.17 Compressor oil cooling systems

Details different systems for controlling compressor oil temperature.

4.33 Economiser, high-stage (optional)

Explains the economiser option for increased system capacity and efficiency.

4.34 General piping diagram

Provides general piping diagrams for the unit.

5. Physical and connection data

5.1 Physical data

Provides dimension sketches and tables for the equipment.

5.2 Allowable flange loads

Specifies allowable axial, torque, and load components for flanges.

5.3 Mounting of suction isolation valve

Details the correct placement and installation of the suction isolation valve.

5.4.1 Connections to compressor unit

Provides dimension sketches and tables for compressor unit connections.

5.4.2 Electrical connections

Illustrates the positions of electrical connections on the unit.

6. Technical data

6.1 Data for compressor units

Provides technical data including dimensions and weights for compressor units.

6.3 Planning the machine room

Offers guidance on planning the machine room for adequate space.

6.5 Operating limits

Shows an example of the permissible working range for a compressor.

6.6 Selecting electric motor

Discusses considerations for selecting the appropriate electric motor.

6.13 Noise data

States noise data including SWL and SPL values.

6.15.2 Test pressure levels for standard compressors and components

Details standard test pressure levels for compressors and components.

7. Installation instructions

7.2 Safety precautions

Emphasizes reading safety precautions before installation.

7.4 Installation and first start-up procedure

Outlines mechanical, electrical, and safety equipment installation requirements.

7.17 Alignment of compressor and motor

Explains the importance and methods for aligning the compressor and motor.

7.23 Damping using vibration dampers

Details how to use vibration dampers for reducing vibrations effectively.

7.30 Pressure testing

Describes the procedure for pressure testing the refrigeration plant and unit.

8. Components

Motor

Describes motor types, supply voltage, and protection class.

Oil separator

Details the oil separator and its internal piping connections.

8.1 UniSAB III

Describes the UniSAB III control system and its sensors.

9. Settings

9.1 Control system

Covers the UniSAB III system and notes on factory settings.

10. Operating instructions

11. Maintenance instructions

11.1 Safety precautions

Emphasizes reading safety precautions before performing any maintenance.

11.2 Maintenance of compressor unit

Outlines daily, periodic, and major overhaul maintenance tasks.

11.3 Stopping routine

Describes procedures for stopping and starting up the compressor.

11.7 General rules for use of lubricating oil in refrigeration compressors

Provides rules for selecting and using lubricating oil in refrigeration compressors.

11.12 Charging compressor with lubricating oil

Details the procedure for charging the compressor with lubricating oil.

12. Faultfinding instructions

12.1 How to carry out faultfinding

Explains the situations and methods for carrying out faultfinding.

12.2 Troubleshooting

Provides tables for troubleshooting common problems in refrigeration plants and compressor units.

13. Service instructions

14. Transport instructions

14.1 Safety precautions

Highlights dangers and safety precautions related to transport.

14.2 Transport data

Provides weight and dimensions for transport.

14.4 Handling of compressor and unit

Details how to handle the compressor and unit safely.

14.5 Loading instructions

Provides instructions and warnings for lifting and loading the unit.

14.12 Storage

Outlines provisions for storing the unit, including protective measures.

15. Commissioning instructions

15.1 Safety precautions

Emphasizes safety precautions before commissioning.

15.2 Preparations for commissioning

Covers final installation checks and personnel requirements.

15.4 Evacuation and charging of refrigerant

Details the process of evacuating and charging refrigerant.

15.5 Start-up

Provides instructions for starting up the plant.

15.7 Commissioning checklist

A checklist for verifying operations before and after start-up.

16. Spare parts list

16.1 Please see separate spare parts manual

Directs users to a separate manual for spare parts information.

17. Spare parts drawings

17.1 Please see separate spare parts manual

Directs users to a separate manual for spare parts drawings.

18. Final disposal

18.1 Safety precautions

Outlines safety precautions to be taken before dismantling the plant.

18.2 Waste disposal

Provides guidelines for the proper disposal of machine parts, oil, refrigerant, and electronics.

19. Appendices

1. List of torque

Includes torque tables for screws and bolts.

3. Diagrams and sketches

Refers to order-specific diagrams and sketches for piping, wiring, and layout.

4. Electric motor

Provides instructions for electric motors.

Johnson Controls Frick SGC 1913 Specifications

General IconGeneral
BrandJohnson Controls
ModelFrick SGC 1913
CategoryAir Compressor
LanguageEnglish