TC-15001-rev.3
iii
Installation Precautions
To reduce the risk of serious injury or death, the following installation
precautions must be followed.
Ɣ When installing the unit into…
ƕ $ZDOO0DNHVXUHWKHZDOOLVVWURQJHQRXJKWRKROGWKHXQLW¶VZHLJKW,WPD\EHQHFHVVDU\WR
construct a strong wood or metal frame to provide added support.
ƕ A room: Properly insulate any refrigerant tubing run inside a room to prevent “sweating” that can
FDXVHGULSSLQJDQGZDWHUGDPDJHWRZDOODQGÀRRUV
ƕ Damp or uneven areas: Use a raised concrete pad or concrete blocks to provide a solid, level
foundation for the unit to prevent water damage and abnormal vibration.
ƕ An area with high winds: Securely anchor the outdoor unit down with bolts and a metal frame.
3URYLGHDVXLWDEOHDLUEDIÀH
ƕ A snowy area (only for Heat Pump Model): Install the outdoor unit on a raised platform that is
higher than drifting snow. Provide snow vents.
Ɣ If the remote sensors are not used with this controller, then do not install this controller…
ƕ in a room where there is no thermostat.
ƕ where the unit is exposed to direct sunshine or direct light.
ƕ where the unit will be in close proximity to a heat source.
ƕ where hot/cold air from the outdoors, or a draft from elsewhere (such as air vents, diffusers or
grilles) can affect air circulation.
ƕ in areas with poor air circulation and ventilation.
Ɣ 'RQRWLQVWDOOWKHXQLWLQWKHIROORZLQJSODFHV'RLQJVRFDQUHVXOWLQDQH[SORVLRQ¿UHGHIRUPDWLRQ
corrosion, or product failure.
ƕ ([SORVLYHRUÀDPPDEOHDWPRVSKHUH
ƕ :KHUH¿UHRLOVWHDPRUSRZGHUFDQGLUHFWO\HQWHUWKHXQLWVXFKDVLQFORVHSUR[LPLW\RUGLUHFWO\
above a kitchen stove.
ƕ Where oil (including machinery oil) may be present.
ƕ :KHUHFRUURVLYHJDVHVVXFKDVFKORULQHEURPLQHRUVXO¿GHFDQDFFXPXODWHVXFKDVQHDUDKRW
tub or hot spring.
ƕ :KHUHGHQVHVDOWODGHQDLUÀRZLVKHDY\VXFKDVLQFRDVWDOUHJLRQV
ƕ Where the air quality is of high acidity.
ƕ Where harmful gases can be generated from decomposition.
Ɣ Do not position the drain pipe for the indoor unit near any sanitary sewers where corrosive gases
may be present. If you do, toxic gases can seep into breathable air spaces and can cause respiratory
LQMXULHV,IWKHGUDLQSLSHLVLQVWDOOHGLQFRUUHFWO\ZDWHUOHDNDJHDQGGDPDJHWRWKHFHLOLQJÀRRU
furniture, or other possessions may result. If condensate piping becomes clogged, moisture can back
up and can drip from the indoor unit. Do not install the indoor unit where such dripping can cause
moisture damage or uneven locations: Use a raised concrete pad or concrete blocks to provide a
solid, level foundation for the unit to prevent water damage and abnormal vibration.
Ɣ %HIRUHSHUIRUPLQJDQ\EUD]LQJZRUNEHVXUHWKDWWKHUHDUHQRÀDPPDEOHPDWHULDOVRURSHQÀDPHV
nearby.
Ɣ Perform a test run to ensure normal operation. Safety guards, shields, barriers, covers, and protective
GHYLFHVPXVWEHLQSODFHZKLOHWKHFRPSUHVVRUXQLWLVRSHUDWLQJ'XULQJWKHWHVWUXQNHHS¿QJHUVDQG
clothing away from any moving parts.
Ɣ &OHDQXSWKHVLWHZKHQ¿QLVKHGUHPHPEHULQJWRFKHFNWKDWQRPHWDOVFUDSVRUELWVRIZLULQJKDYH
been left inside the unit being installed.
Ɣ During transportation, do not allow the backrest of the forklift make contact with the unit, otherwise,
it may cause damage to the heat exchanger and also may cause injury when stopped or started
suddenly.
Ɣ 5HPRYHJDVLQVLGHWKHFORVLQJSLSHZKHQWKHEUD]LQJZRUNLVSHUIRUPHG,IWKHEUD]LQJ¿OOHUPHWDOLV
melted with remaining gas inside, the pipes will be blown off and it may cause injury.
Ɣ Be sure to use nitrogen gas for an airtight test. If other gases such as oxygen gas, acetylene gas or
ÀXRURFDUERQJDVDUHDFFLGHQWDOO\XVHGLWPD\FDXVHH[SORVLRQRUJDVLQWR[LFDWLRQ
After installation work for the system has been completed, explain the “Safety Precautions,” the proper use
and maintenance of the unit to the customer according to the information in all manuals that came with the
system. All manuals and warranty information must be given to the user or left near the Indoor Unit.

Table of Contents

Other manuals for Johnson Controls HIDH018B21S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls HIDH018B21S and is the answer not in the manual?

Johnson Controls HIDH018B21S Specifications

General IconGeneral
BrandJohnson Controls
ModelHIDH018B21S
CategoryAir Conditioner
LanguageEnglish

Related product manuals