Engineering manual - SAB 355 Screw compressor unit (including ATEX)
004100 en 2020.10
129/156
Maintenance instructions
Parameter Unit Method
Sabroe oil
PAO 68
Sabroe oil
AP 68
Sabroe oil
A 100
Tar-
get
spec.
Max.
Min.
Tar-
get
spec.
Max.
Min.
Tar-
get
spec.
Max.
Min.
Viscosity @40°C cSt ASTM D 445 66 76 53 64 74 51 100 115 80
TAN*1) mg KOH/g ASTM D 664 0.03 0.2
-
0.01 0.02
-
0.05 0.02
-
SAN*2) mg KOH/g ASTM D 665
-
0
- -
0
- -
0
-
Water
ppm
Karl Fisher
-
100
- -
100
- -
100
-
Apperarance
- - re-
port
re-
port
re-
port
Colour
-
ASTM D
1500
re-
port
re-
port
re-
port
Pentane Insolubles
(Sum)
W% MM 490
-
0.05
-
0.05
- -
0.05
-
Oxidation abs/cm IR,1700-
1720/cm
-
5
- -
5
- -
5
-
Nitration
abs/cm IR,1627-
1637/cm
-
5
- -
5
- -
5
-
Nitro Compounds abs/cm
IR,1547-
1557/cm
-
0.5
- -
0.5
- -
0.5
-
Maximum values for metal content in the oil)
Lead
ppm
ICP
-
10
- -
10
- -
10
-
Copper
ppm
ICP
-
10
- -
10
- -
10
-
Silicium
ppm
ICP
-
25
- -
25
- -
25
-
Iron
ppm
ICP
-
100
- -
100
- -
100
-
Chromium
ppm
ICP
-
5
- -
5
- -
5
-
Aluminium
ppm
ICP
-
10
- -
10
- -
10
-
Tin
ppm
ICP
-
10
- -
10
- -
10
-
1) TAN (Total Acid Number) is only non-ammonia applications
2) SAN (Strong Acid Number) is only reported for non-ammonia applications
A report is compiled for every sample received. This report will describe:
whether the oil can still be used without taking any further action.
whether the oil can be used after it has been filtered through a very fine filter. If this is nec-
essary, the oil must be pumped directly from the compressor unit through a 3 micron filter
and back to the unit. The system must be completely closed to prevent the oil from being
affected by moisture in the air.
whether the oil can no longer be used.
The report will always be sent to the address stated on the sample label included in the form set.
A copy will be sent to Johnson Controls Denmark so that we are in a position to advise you, if
required.
11.13 Oil change
The oil in the unit must be changed after a specific number of operating hours or when an oil anal-
ysis shows that a change is required.
We advise you to contact your local Johnson Controls representative about oil change as it is rec-
ommended to replace all filters in the unit at the same time. Local contact details are available on
www.sabroe.com.