13
Note:
The travel limit position must be settled according to the gate travel length after the first installation
of the gate opener.
5.3.1 Operation Instruction for Travel Limit Position Setting:
A. Operation Instruction
1. Enter into Setting Mode:
a. Press “-” button for 3 sec. to enter into travel limit position setting. All indicator lights L1-L5
will flicker simultaneously.
b. Press “SET” button once to confirm to reset the travel limit position. The indicator lights will
be on in sequence from L5 to L1.
2. Gate Closing Limit Position Setting:
c. Press and hold “-” button to enable the gate to run to its appropriate closing limit position. Then
release the “-” button to stop running. Through pressing the “-” or “+” button, the closing limit position
can be adjusted accurately. (If the gate runs to its opening direction after pressing the “-”
button, please press “PROG” button to exit the travel limit position setting first, then
exchange the motor wires and re-start to set the limit position)
d. Press “SET” button to confirm the closing limit position. The indicator lights will be on in
sequence from L1 to L5.
3. Gate Opening Limit Position Setting:
e. Press and hold “+” button to enable the gate to run to its appropriate opening limit position, then
release the “+” button to stop running. Through pressing the “-” or “+” button, the opening limit
position can be adjusted accurately
f. Press “SET” button to save the settings and exit automatically. The indicator lights L1-L5 will
be on for one sec.