Section 6 Setting Up Alerts 6-6
6.4 Setting Up Alert Processing
When [AMS] is selected in the Classification pane, the [AMS] dialog is displayed in the Edit pane.
In this dialog, the time to activate the action at the next stage when acknowledge is not performed for
an alert can be set up.
Enter the wait time until an alert at the next stage is generated in [Time Limit].
Reactivation of Silenced Alert:
Set, in the range between 0 and 60s, the time required to reactivate the alert sound that was silenced
temporarily.
Transfer to BNWAS:
When a BNWAS (Bridge Navigational Watch Alarm System) is connected, specify the time to transfer
an unacknowledged alert to the BNWAS in the range between 0 and 30s.
Repetition of UNACK Warning:
Specify the time to regenerate an unacknowledged alert as an audible warning in the range between 0
and 300s. A warning will be generated repeatedly until it is acknowledged.