8-11 Section 8    Adjusting and Setting Up Equipment (for Services) 
 
 
 
1 
2 
3 
4 
5 
6 
7 
8 
9 
10 
11 
12 
13 
14 
15 
16 
17 
18 
20 
21 
22 
23 
24 
25 
APP A
 
APP B 
 
 
 
The setting target can be checked with [Source Device] display, [Terminal] display and [Sensor] 
display. 
Perform the settings shown in the following table and then click on the [Set] button. 
 
Setting Item  Description of Setting  Setting Value 
Baud Rate  Select the baud rate of the corresponding serial 
port from the combo box. 
In the [Detail] dialog of any of CH8 to CH10, the 
[Baud Rate] addition ratio combo box is 
displayed on the right side of the [Baud Rate] 
combo box. 
Selectable baud rates vary 
depending on the serial port 
(Refer to "Baud rates that 
can be selected".) 
[Baud Rate] addition ratio 
combo box 
Displayed in the [Detail] dialog of CH8 to CH10. 
By using this combo box, the addition ratio (%) 
for adjusting the baud rate can be changed. The 
baud rate for communication is determined by 
adding the additional ratio to the value that is set 
in the [Baud Rate] combo box. 
Example) 4800 × (1 + 1.5 / 100) = 4872 
 Additional ratio 
0.0% to 3.0% (can be set in 
the unit of 0.5%) 
 
Data Length  Select the data length of the corresponding serial 
port from the combo box. 
5/6/7/8 
Parity  Select the parity of the corresponding serial port 
from the combo box. 
None/Odd/Even 
Stop Bits  Select the stop bit length of the corresponding 
serial port from the combo box. 
1/2 
Buffer Size  Enter the buffer size of the corresponding serial 
port in the box. 
0 to 10240 bytes 
Time Out  Enter the time-out duration of the corresponding 
serial port in the box. 
0 to 999s 
Checksum  Select the check box and enable the checksum 
of the sentence of the corresponding serial port. 
To enable: Select. 
To disable: Clear. 
Subsystem  Set the equipment to be connected for Alert 
Handling. 
Displayed only when the sensor is "Alert (from 
Subsystem)" or "Alert (to CAM)". 
The selection is also allowed for the subsystem 
that has already been used in the channel of 
some other serial port. 
"Alert (from Subsystem)": 
Equipment that is set as   
-/installed (Task Station and 
sensor) 
"Alert(to CAM)": 
Equipment that is set as 
-/installed (Task Station) 
Primary/Secondary Select Primary or Secondary for IAS(MODBUS) 
input. 
Displayed only when the sensor is 
"IAS(MODBUS)". 
Primary: Primary system 
Secondary: Secondary 
system 
Sentence  Select the sentence of Alert Handling. 
Displayed when the sensor is other than "Alert 
(BNWAS), "IAS(MODBUS)", "DSC" or 
"NAV/Alert".  
 
Normal sensor such as GPS 
and Log: 
-/ALR/ALF 
"Alert (from Subsystem/to 
CAM)": 
ALR/ALF