2-28
[Data IN/OUT 1 Connector]
DATA IN/OUT 1 (Label name of the back of Display)
Data Cable: CFQ-5374 (option)
Terminal
Number
(CFQ-5374)
Name Explanation
1 (Brown)
Unused
2 (Red)
3 (Orange)
Sensor
Through
SD-A
Output signal is sent from this terminal by
connecting the sensor.
Outputs as defined by "Sensor Through"
configuration.
(Refer to "5.3.7 Data I/O Settings (DATA I/O)")
4 (Yellow) SD-B
5 (Green) SC-A Outputs clock when AD-10 configuration is
performed for "Sensor Through".
This port is not used excluding AD-10. (*1)
6 (Blue) SC-B
7 (Purple)
DATA OUT3
(TXD3)
A
Outputs as defined by "Data OUT 3"
configuration.
(Refer to "5.3.7 Data I/O Settings (DATA I/O)")
8 (Grey) B
9 (White)
Unused
10 (Black)
11 (Pink)
GND
ISO
Connects serial transmission cable ground.
12 (Light Blue) GND Chassis ground
*1: 4 pins are used for AD-10. Refer to “Output of AD-10 Format” in “5.3.7 Data I/O Settings
(DATA I/O)” for details.
Appearance of Connection Cable
A
B
External Device
Approx.Φ6.5mm
Approx.Φ18mm
CFQ-5374
CFQ5374-15
CFQ-5374 3m
CFQ5374-15 15m
Shield for cable
Connector
Product by LTW : LTWCD-12BFFA-LI80