– 59 –
Switch/display Description
A Sewing recorder graph
display
The graph the vertical axis of which shows the sewing speed and the horizontal
axis of which shows the time is displayed. The ranges of the vertical and hori-
zontal axes can be set on the sewing recorder screen No. 2.
Point
represents the sewing starting point, thread trimming point or the man-
ual-switch pressing point in the data No.1.
Point
represents the starting and end points of the pitch time of the data
No.1.
Point
represents the sewing starting point, thread trimming point or the man-
ual-switch pressing point in the data No.2.
Point
represents the starting and end points of the pitch time of the data
No.2.
B
Sewing recorder screen No.
1
The sewing recorder data No. 1 is shown on the graph in solid lines --------.
C
Sewing recorder screen No.
2
The sewing recorder data No. 2 is shown on the graph in dotted lines -----.
D Pitch time display of data
in the screen
The pitch time of the sewing work in which the last thread trimming, on the cur-
rent screen, is performed is displayed.
Upper display : Data No. 1
Lower display : Data No. 2
Production volume count-
up switch
The production volume is counted up with one item added.
Active data selector switch Active data (data to be shifted with switch
or
, data to be additionally re-
corded when sewing operation is carried out, or data which can be cleared with
Clear switch
on the screen No. 2) is selected.
Setting only data No. 1
to be active :
Setting only data No. 2 to
be active :
Setting both data to be
active :
Graphs Nos. 1 and 2 dis-
play/non-display change-
over switch
Graphs No. 1 and No. 2 are respectively changed over between the display and
non-display.
Display :
Non-display :
Right/left scroll switch Data graph that is set to be active is displayed with scrolled to the right or left.
Latest work data display
switch
The latest work of the data which is set to be active is displayed in a graph from
the beginning of sewing.
Display changeover
switch to display the sew-
ing recorder screen No. 2
The sewing recorder screen No. 2 is displayed.
Production volume count-
er correction switch
The production volume can be corrected by increasing/decreasing the number
shown on the counter in increments of 1.
Explanation of displayed information and operating switches on the sewing recorder screen No. 1