1298.GB
D 4
5 Checking battery condition, acid level, and acid density
The service instructions of the battery supplier apply.
Check the battery casing for cracks and acid leaks.
Remove oxidation residues from the battery terminals and lightly grease with acid-
free pole grease.
Screw out the screw caps and check the acid level.
The acid level must be a minimum of 10-15mm above the plate top.
Check the acid density according to the suppliers specifications with an acid pipette
and subsequently remount the screw caps.
If necessary, recharge the battery.
6 Battery discharge indicator
After turning the key in the key-operated
switch to the right and pulling the emer-
gency stop switch, the battery discharge
indicator steplessly displays the remai-
ning capacity. The indicator is flashing at
a remaining capacity of 30 %. If the ca-
pacity indication falls below 20 %, the lif-
ting unit is switched off.
+-
50%
1298.GB
D 4
5 Checking battery condition, acid level, and acid density
The service instructions of the battery supplier apply.
Check the battery casing for cracks and acid leaks.
Remove oxidation residues from the battery terminals and lightly grease with acid-
free pole grease.
Screw out the screw caps and check the acid level.
The acid level must be a minimum of 10-15mm above the plate top.
Check the acid density according to the suppliers specifications with an acid pipette
and subsequently remount the screw caps.
If necessary, recharge the battery.
6 Battery discharge indicator
After turning the key in the key-operated
switch to the right and pulling the emer-
gency stop switch, the battery discharge
indicator steplessly displays the remai-
ning capacity. The indicator is flashing at
a remaining capacity of 30 %. If the ca-
pacity indication falls below 20 %, the lif-
ting unit is switched off.
+-