Locks – Using and Programming
Kaba Ilco Lodging Access Control System 141
7. Scroll through the list of addresses using the <S> and <T> keys to view the
Common Door, Section, Floor, Group, Zone and Area Addresses.
NOTE: The Common Door address must match the list of addresses
programmed at the factory for the Common Doors of Common Door Suites.
8. Enter the new address. Change other addresses if necessary, and press < >
when ready to program the lock.
9. Insert the Programming keycard in the lock, and ensure the green indicator is lit.
Connect the communication cable from the FDU to the lock and press any key
on the FDU to send the programming to the lock.
The addresses are now assigned. Every time lock addresses are programmed, the
FDU sets the lock’s internal clock to the correct time, so there is no need to reset
the lock time. Remove the communication cable from the lock. The FDU will
return to the Common Door Suite menu and shows the previous values used for
the lock.