Locks – Using and Programming
Kaba Ilco Lodging Access Control System 161
3. Press 1 or < > to reach the “Lock Programming” menu.
4. Press 7 or use the down <T> arrow followed by < > to reach the “Electronic
Override” menu.
5. Press < > to communicate with the lock and perform the override.
5.7.3 Overriding a RAC Card Reader
RACs control electrical devices such as magnetic locks, motorized doors and elevators,
using relays. There is an ON/OFF override switch built into the RAC panel box. Each
individual device should have an appropriate override installed to meet safety codes. An
elevator, for example, should have a stop button.
5.8 The FDU Override
As an alternative to mechanical and electrical overrides, the FDU provides an easier way
to override the privacy of 760, 770, and 710-II lock models. When the lock is
programmed with the override privacy feature, any staff employee may unlock this lock.
This is known as the “Global Australian Privacy Override” as this is typically only for