EasyManua.ls Logo

Kaba ILCO FDU - Page 161

Kaba ILCO FDU
276 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5
150 Kaba Ilco Lodging Access Control System
Equipment required: FDU
Lock communication cable
Initialization keycard
Programming keycard
Completed Planning Forms
Minimum keycard required: Programming Authorization
Steps to program the Restricted Area lock addresses:
1. If this is a first time installation, or if power to the lock has been interrupted,
insert the Initialization keycard in the lock. The red and green indicators
should light, then only the green indicator should flash. Re-insert the
Initialization keycard if the pattern of indicator lights described is not
observed.
2. Swipe a keycard or enter a PIN value having a Programming authorized
user level.
3. Press 8 or use the down <T> arrow followed by < > to reach the
“Programming FDU/Lock” menu.
4. Press 1 or < > to reach the “Lock Programming” menu.
5. Press 5 or use the down <T> arrow followed by <
> to reach the
“Programming Restricted Areas” menu.
NOTE:
The initialization
keycard starts up the
PCB. It does not
prepare the board fo
r
programming

Table of Contents

Other manuals for Kaba ILCO FDU

Related product manuals