Reset Keycard Available
Maximum Addresses
Minimum Authorization
Required
Selectable Expiry
Factory Default Expiry
Variable Expiry
Guest Common Areas
Salesman's Lockout
Staff Common Areas
Time Zone On Keycard
Menus Navigation & Options
1
Guest
Yes 16,000 FDA 1 hr to 2730 night
1 nigh
Yes 8 Yes -
FDA/1/1/Room#...
2
One-Shot
Yes 16,000 FDA 1 hr to 4 hr
1 h
No - No -
FDA/1/2/Room#... For Guest Rooms only
3
Adjoining Suite
Yes 16,000 FDA 1 hr to 2730 night
1 nigh
Yes 8 Yes -
FDA/1/3/Starting Room#...
4
Common Door Suite
Yes 1,000 FDA 1 hr to 2730 night
1 nigh
Yes 8 Yes -
FDA/1/4/Suite#...
5
Convention Suite
Yes 1,000 FDA 1 hr to 2730 night
1 nigh
Yes 8 Yes -
FDA/1/5/Convention Suite#...
6
Pre-registered
Yes 16,000 FDA 1 hr to 2730 night
1 nigh
Yes 8 Yes -
FDA/1/6/Guest or Adj. or Comm. Door...
7 Restricted Area Yes 200
MA 1 night to 2730 night
1 nigh
No - No -
MA
1
7
...
8
Section
Yes 255 MA 1 night to 2730 night
365 night
- *** ** 16 6
MA/1/8/Section#...
9
Floor
Yes 255 MA 1 night to 2730 night
365 night
- *** ** 16 6
MA/1/9/Floor#...
10
Group
Yes 255 MA 1 night to 2730 night
365 night
-
*** ** 16 6
MA/1/10/Group#...
11
Zone
Yes 255 MA 1 night to 2730 night
365 night
- *** ** 16 6
MA/1/1 1/Zone# ...
12
Area
Yes 255 MA 1 night to 2730 night
365 night
-
16 6
MA/1/12/Area#...
13
Bellman's Master
Yes 1 BA/GMA 1 hr to 24 hr
24 hrs - None ** None
ll
BA or GMA/1/13
14
Grand Master
Yes 1 GMA 1 night to 2730 night
365 night
-
ll **
ll
ll
GMA/1/14
15
Emergency
Yes 1
MA 1 night to 2730 night
365 night
-
ll †
ll
ll
GMA/1/15
16
Front Desk (FDA)
No 100 MA None - - - - - -
MA/1/16
17
Bellman's (BA)
No 40 GMA None - - - - - -
GMA/1/17
18
Programming (PA)
No 20 GMA None - - - - - -
GMA/1/18/2
18
Master (MA)
No 20 GMA None - - - - - -
GMA/1/18/1
19
Grand Master (GMA)
No 20 GMA None - - - - - -
GMA/1/19
30
POS
Yes 200 MA None - - - - - -
MA/1/30
*
Salesman's
- - FDA - - - - - - -
Not a keycard*
20
Hotel
No 1 GMA 1 hr to 2730 night
24 hrs - - - - -
GMA/1/20
21
Room
No 16,000 GMA 1 hr to 24 hr
24 hrs - - - - -
GMA/1/21
22
Group
No 255 MA 1 night to 2730 night
365 night
-- ---
MA/1/22 for locking out guests who have checked out.
23
Battery Test
No
ll FDA None - - - - - -
FDA/1/23
24
Programmiing
No
ll PA 1 night to 2730 night
2730 night
-- ---
PA/1/24
25
Passage
Yes 16,000 MA 1 night to 2730 night
1 nigh
-- ---
MA/1/25
26
Hotel Restart
No 1 GMA 1 hr to 24 hr
24 hrs
27
FDU Cancel
No 1 GMA 1 hr to 24 hr
24 hrs
28
Installation
(1)
Test
No 1 PA None - - - - - -
PA/1/28/1 Expiry 2730 nights recommended
(2)
Initialization
No 1 PA None - - - - - -
PA/1/28/2
31
Audit Lock
No 1 PA None
------
PA/1/31 SolitaireSMART only
* The Salesman's Lockout is not a keycard but rather an option on the Guest or Suite keycard (consult the manual).
** Will not override the Salesman's Lockout, Room or Hotel Lockout, or deadbolt.
*** The FDU features can be set to encode access to either all 8, or none of the Guest Common Areas on Sub-Master level (Staff) Keycards.
† Will override the Salesman's Lockout, Room or Hotel Lockout, or deadbolt.
CALL KABA ILCO SERVICE LINE FOR ASSISTANCE
Lockout / Unlock
Special Purpose
Master Level Access
Authorization
Appendix A: Keycard Quick Reference Guide
Sub-Master Level Access
Guest Level Access
Rest. Area Level Access