Front Desk Units - Using and Programming 
Kaba Ilco Lodging Access Control System    33
Steps to transfer data to another FDU: 
1. Label the two Front Desk Units to differentiate the one that must receive the data 
(new) from the one that must send the data (old or Master FDU). 
2. As a property may have previous versions of Kaba’s FDU system as well as the new 
generation model different types of cables may be required for the FDU to FDU 
transfer. If the version of FDU is unknown please contact Kaba Technical Support. 
Based on the table below, connect the required FDU to FDU communication cable to 
the Serial Port on the rear panel of each Front Desk Unit.  
Sending FDU version  Receiving FDU version  Required cable 
Previous Generation  Previous Generation Straight serial cable 
Previous Generation  Next Generation Straight serial cable 
Next Generation  Previous Generation  Null modem cable 
Next Generation  Next Generation  Null modem cable 
3. On the FDU that will receive data, swipe a keycard having a GMA or MA authorized 
user level. 
4. Press 8, or use the down <T> arrow followed by < > to reach the “Programming 
FDU/Lock” menu. 
5. Press 2, or use the down <T> arrow followed by < > to reach the “Another FDU” 
menu.