SAM
®
RF Operations Manual 112
Section 5: Keys
© SAFLOK WL 12/20/2007
Creating an Inhibit Master Key (continued)
6. At the Select User Type PC dialog box, click the open circle next to
Staff and click OK.
Note: Inhibit Master keys can only be assigned to staff members.
7. Staff members you previously entered
into the system will be listed in this box.
Simply click on the name of the person to
receive this new key and click Select.
8. Back at the Create Inhibit Master Key PC dialog box, the name of the person you selected will appear
in the box under The Key Is Assigned To. When you are satisfied with the settings for this inhibit
Master key, insert a key, and then click OK.
Note: You must keep the key in the electronic key encoder base while the key image
spins on the PC screen.
Note: If a key is not currently in the electronic key encoder, the PC will display an error screen until you
insert a key into the electronic key encoder.
Note: You must keep the USB cable connected between the electronic key encoder base and the PC
while the key image spins on the PC screen. The PC screen will display, “The write operation was
successful!