20 Kamstrup A/S • 5512952_C6_GB_07.2015
MULTICAL® 602 & ULTRAFLOW®
9.2 Bse modules
9.2.1 Dt + pulse inputs, type 67-00-10
The dt terminls re used for connection of
e.g. PC. The signl is pssive nd glvniclly
seprted by mens of optocouplers.
Conversion into RS232 level requires
connection of dt cble 66-99-106 (D-Sub
9F) or 66-99-098 (USB) using the following
connections:
62 Brown (DAT)
63 White (REQ)
64 Green (GND)
The pulse inputs cn be used for connection of electricity nd wter meters.
Plese py ttention to mximum pulse frequency s well s correct pulse coding (l/imp. nd
Wh/imp.), which is selected by mens of the FF nd GG configurtion.
65 - 66 Input A
67 - 68 Input B
9.2.2 M-Bus + pulse inputs, type 67-00-20/27/28/29
M-Bus cn be mounted in str, ring or bus topology. Up to 250 meters cn be connected
depending on the M-Bus Mster’s power supply nd the totl cble resistnce.
Cble resistnce < 29 Ohm
Cble cpcity < 180 nF
The M-Bus network is connected on terminls
24 nd 25. The polrity is unimportnt.
M-Bus comes with pulse inputs.