EasyManuals Logo

KEB combivert R6-S Applications Manual

KEB combivert R6-S
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #108 background imageLoading...
Page #108 background image
Page3.7 - 4 COMBIVERT R6-S © KEB, 2008-02
Parameter sets
3.7.4 Copying of parameter sets via keyboard (Fr.01)
0. Fr. 1
1. Fr. 1
2. Fr. 1
3. Fr. 1
4. Fr. 1
5. Fr. 1
6. Fr. 1
7. Fr. 1
DOWN
UP
Adjust target set
A
Fr
·
1
Change with Func.
to source
1
2
3
4
5
6
7
DOWN
UP
Adjust source set
0
dEF_S
ini_A
ini_S
dEF_A
The target set 0...7 is adjusted with the
keys UP/Down at blinking dot next to the
parameter set number. The active (A)
parameter set may not be adjusted as
target set when copying. If the target set
is> 0, only the programmable parame-
ters are overwritten!
The source set is adjusted with the keys
UP/Down. The copy process is started
with „Enter“. Copy process is only pos-
sible with open control release or error,
otherwise "I_op" (invalid operation) is
displayed.
„PASS“ is displayed after the copy pro-
cess. This message can be deleted with
„ENTER“.

Table of Contents