Long Integration Measurements 4-9
The three trigger level ranges are displayed as follows using the TRIGGER LEVEL menu
option:
5A Range: LINT T
RIG LEVEL #1
A (5.0) 0.000A
1A Range: LINT T
RIG LEVEL #1
A (1.0) 0.000A
100mA Range: LINT T
RIG LEVEL #1
mA (100) 0.0000A
For Model 2306-PJ (battery channel #1) 500mA current range — The trigger
level can
be set for either the 500mA, 100mA, or 10mA range. For the 500mA range, the trigger level can
be set from 0 to 500mA in 0.5mA steps. For the 100mA range, the trigger level can be set from
0 to 100mA in 0.1mA steps. For the 10mA range, the trigger level can be set from 0 to 10mA in
0.1mA steps.
The three trigger level ranges are displayed
as follows using the TRIGGER LEVEL mA
menu option:
500mA Range: LINT T
LEV mA #1
mA (500) 0.0000A
100mA Range: LINT T
LEV mA #1
mA (100) 0.0000A
10mA Range: LINT T
LEV mA #1
mA (10) 0.0000A
To toggle the range for the trigger level, place the blinking cursor on the “A” at the far right
end
of line two of the display, and press the
▲ and ▼ key. After keying in the trigger level (in
amps), press ENTER to update the displayed range for that trigger level setting only.
Charger Channel (#2) — Set the trigger le
vel from 0 to 5A in 5mA steps.
Trigger level range
TRIGGER LEVEL RANGE is a battery channel (#1) setting only. Use to specify the trigger
level range. On the 5A current range (Models 2306, 2306-VS, and 2306-PJ), possible Trigger
Level Ranges are:
5A FULL SCALE (0–5A)
1A FULL SCALE (0–1A)
100mA FULL SCALE (0–100mA)
For the 500mA current range (Model 2306-PJ), using
the TRG LEV mA RANGE menu
option, possible trigger level ranges are:
500mA FULL SCALE (0–500mA)
100mA FULL SCALE (0–100mA)
10mA FULL SCALE (0–10mA)