OUTPut Subsystem
Command/Query Description
OUTPut[:STATe] ON|1|OFF|0
OUTPut[:STATe]?
Enables or disables the instrument's output.
OUTPut:COUPling AC|DC|ACDC
OUTPut:COUPling?
Sets the output coupling mode.
OUTPut:PON:STATe RST|RCL0|AUTO
OUTPut:PON:STATe?
Sets the power-on output state.
OUTPut:PROTection:CLEar Resets the latched protection.
OUTPut:PROTection:WDOG[:STATe] ON|1|OFF|0
OUTPut:PROTection:WDOG[:STATe]?
Enables or disables the I/O watchdog timer.
OUTPut:PROTection:WDOG:DELay <value>|MINimum|MAXimum
OUTPut:PROTection:WDOG:DELay? [MINimum|MAXimum]
Sets the watchdog delay time.
SENSe Subsytem
Command/Query Description
SENSe:AVERage1|2|4|8|16
SENSe:AVERage?
Sets the averaging count for measurements.
SENSe:CURRent[:PEAK]:HOLD:CLEar Clears the peak held current measurement.