2 kW Characteristics
N7970A N7971A N7972A N7973A N7974A
Current programming & measurement
TempCo
2
High range:
Low range:
0.0029%+500µA
0.0040%+160µA
0.0031%+250µA
0.0041%+80µA
0.0035%+120µA
0.0045%+40µA
0.0032%+80µA
0.0042%+24µA
0.0032%+60µA
0.0041%+18µA
Resistance programming
TempCo: 0.0043% 0.0045% 0.0049% 0.0046% 0.0045%
Over-Voltage Protection
Maximum setting:
Response time:
3
Accuracy:
10.8 V
<30 µs
0.03% +1 mV
24 V
<30 µs
0.03% +2 mV
48 V
<30 µs
0.03% +4 mV
72 V
<30 µs
0.03% +6 mV
96 V
<30 µs
0.03% +8 mV
Voltage measurement noise (peak):
4
2 mV 3.5 mV 7 mV 10 mV 14 mV
Current measurement noise (peak)
4
High range:
Low range: 75 mA
50 mA
45 mA
30 mA
18 mA
12 mA
12 mA
6 mA
7 mA
3 mA
Common mode current
5
CC rms:
CC peak-to-peak:
2 mA
15 mA
1 mA
10 mA
1 mA
10 mA
1 mA
10 mA
2 mA
10 mA
Voltage up-
programming time
6
10% to 90%:
Settling time:
8
0.5 ms
1 ms
Voltage down-
programming time
7
90% to 10%:
Settling time:
8
0.35 ms
0.8 ms
Current up- and down-
programming time
9
10% to 90%:
90% to 10%:
2.5 ms
2.5 ms
Output-on delay time
Voltage priority:
with Relay Option on:
Current priority:
with Relay Option on:
12 ms
38 ms
14 ms
46 ms
Line regulation
Voltage:
Current:
< 10 µV
< 10 µA
Small signal bandwidth
Voltage programming:
10
Current programming:
11
Voltage measurement:
Current measurement:
DC to 1 kHz (-1dB);DC to 2 kHz (-3dB)
DC to 70 Hz (-1dB);DC to 120 Hz (-3dB)
DC to 14 kHz (-1dB);DC to 25 kHz (-3dB)
DC to 14 kHz (-1dB);DC to 25 kHz (-3dB)
Keysight N6900/N7900 Series Operating and Service Guide 51
1 Quick Reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies N6972A with Option 301 and is the answer not in the manual?

Keysight Technologies N6972A with Option 301 Specifications

General IconGeneral
BrandKeysight Technologies
ModelN6972A with Option 301
CategoryPower Supply
LanguageEnglish

Related product manuals