[SOURce:]VOLTage:RESistance:STATe 0|OFF|1|ON
[SOURce:]VOLTage:RESistance:STATe?
Enables or disables output resistance programming. Only applies in voltage priority mode.
Parameter Typical Return
0|OFF|1|ON, *RST OFF 0or1
Turns resistance programming on: VOLT:RES:STAT ON
l Requires firmware version B.03.02.1232 and up for models RP793xA and RP794xA.
[SOURce:]VOLTage:SLEW[:IMMediate] <value>|MIN|MAX|INFinity
[SOURce:]VOLTage:SLEW[:IMMediate]? [MIN|MAX]
Sets the voltage slew rate. The slew rate is set in volts per second and affects all programmed
voltage changes, including those due to the output state turning on or off. The slew rate can be set to
any value between 0 and 9.9E+37. For very large values, the slew rate will be limited by the unit's
listed programming speed and bandwidth. The keywords MAX or INFinity set the slew rate to
maximum.
Parameter Typical Return
0 – 9.9E+37, *RST MAX <max value>
Sets the output slew rate to 5 V per second: VOLT:SLEW 5
l The query returns the value that was sent. If the value is less than the minimum slew rate, the min-
imum value is returned. The resolution of the slew setting is the same as the minimum value,
which can be queried using VOLTage:SLEW? MIN. The exact value varies slightly according to cal-
ibration.
[SOURce:]VOLTage:SLEW:MAXimum 0|OFF|1|ON
[SOURce:]VOLTage:SLEW:MAXimum?
Enables or disables the maximum slew rate override. When enabled, the slew rate is set to its
maximum value. When disabled, the slew rate is set to the immediate value set by the VOLTage:SLEW
command. Use VOLTage:SLEW? MAX to query the maximum slew rate that was set.
Parameter Typical Return
0|OFF|1|ON, *RST ON 0or1
Enable the maximum slew rate override: VOLT:SLEW:MAX ON
l The VOLTage:SLEW:MAX command is coupled to the VOLTage:SLEW command. If
VOLTage:SLEW sets the rate to MAX or INFinity, VOLTage:SLEW:MAX is enabled. If the slew rate
is set to any other value, VOLTage:SLEW:MAX is disabled.
Keysight RP7900 Series Operating and Service Guide 239
5 SCPI Programming Reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies RP7900 Series and is the answer not in the manual?

Keysight Technologies RP7900 Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelRP7900 Series
CategoryPower Supply
LanguageEnglish

Related product manuals