EasyManuals Logo

Keysight Technologies RP7900 Series User Manual

Keysight Technologies RP7900 Series
318 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
[:POSitive]
[:IMMediate]
[:AMPLitude] <value> Sets the current limit when in voltage priority mode.
:NEGative
[:IMMediate]
[:AMPLitude] <value> Sets the current limit when in voltage priority mode.
:MODE FIXed|STEP|LIST|ARB Sets the transient mode.
:PROTection
:DELay
[:TIME] <value> Sets the over-current protection delay.
:STARt SCHange|CCTRans Specifies what starts the over-current protection delay timer.
:STATe 0|OFF|1|ON Enables or disables the over-current protection.
:SHARing
[:STATe] 0|OFF|1|ON Enables or disables current sharing on paralleled units. (RP795xA, RP796xA)
:SLEW
[:IMMediate] <value>|INFinity Sets the current slew rate.
:MAXimum 0|OFF|1|ON Enables or disables the maximum slew rate override.
[SOURce:]
DIGital
:INPut
:DATA? Reads the state of the digital control port.
:OUTPut
:DATA <value> Sets the state of the digital control port.
:PIN<1-7>
:FUNCtion <function> Sets the pin function. DIO |DINPut |FAULt |INHibit |ONCouple |OFFCouple |TOUTput
|TINPut
:POLarity POSitive|NEGative Sets the pin polarity.
:TOUTput
:BUS
[:ENABle] 0|OFF|1|ON Enables or disables BUS triggers on digital port pins.
[SOURce:]
FUNCtion CURRent|VOLTage Sets the output regulation - voltage priority or current priority.
[SOURce:]
LIST
:COUNt <value>|INFinity Sets the list repeat count.
:CURRent
[:LEVel] <value>{,<value>} Specifies the setting for each list step.
:POINts? Returns the number of list points.
:DWELl <value>{,<value>} Specifies the dwell time for each list step.
:POINts? Returns the number of list points.
:STEP ONCE|AUTO Specifies how the list responds to triggers.
Keysight RP7900 Series Operating and Service Guide 29
1 Quick Reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies RP7900 Series and is the answer not in the manual?

Keysight Technologies RP7900 Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelRP7900 Series
CategoryPower Supply
LanguageEnglish