:FUNCtion
:CURRent 0|OFF|1|ON Enables/disables external current logging.
:MINMax 0|OFF|1|ON Enables/disables external min/max current logging.
:VOLTage 0|OFF|1|ON Enables/disables external voltage logging.
:MINMax 0|OFF|1|ON Enables/disables external min/max voltage logging.
:PERiod <value> Sets the external datalog integration time.
:FUNCtion
:CURRent 0|OFF|1|ON Enables/disables current measurements.
:VOLTage 0|OFF|1|ON Enables/disables voltage measurements.
:SWEep
:NPLCycles <value> Sets the measurement time in number of power line cycles.
:OFFSet
:POINts <value> Defines the offset in a data sweep for triggered measurements.
:POINts <value> Defines the number of points in a measurement.
:TINTerval <value> Defines the time period between measurement samples.
:WHOur
:RESet Resets the accumulated watt-hour measurement.
:WINDow
[:TYPE] HANNing|RECTangular Selects the measurement window.
[SOURce:]
ARB
:COUNt <value>|INFinity Specifies the number of times the Arb repeats.
:CURRent
:CDWell
[:LEVel] <value>{,<value>}|<Block> Specifies the level of each point in the Arb.
:DWELl <value> Specifies the dwell time of each point in the Arb.
:POINts? Returns the number of points in the Arb.
:FUNCtion
:TYPE CURRent|VOLTage Specifies either a voltage or current Arb.
:TERMinate
:LAST 0|OFF|1|ON Selects the output setting after the Arb ends.
[SOURce:]
CURRent
[:LEVel]
[:IMMediate]
[:AMPLitude] <value> Sets the output current when in current priority mode
:TRIGgered
[:AMPLitude] <value> Sets the triggered output current
:BWIDth
:RANGe 0 | 1 Sets the current compensation. (RP793xA,RP794xA)
:LEVel 0 | 1, <value> Sets the compensation frequency. (RP793xA, RP794xA)
:LIMit
1 Quick Reference
28 Keysight RP7900 Series Operating and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies RP7900 Series and is the answer not in the manual?

Keysight Technologies RP7900 Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelRP7900 Series
CategoryPower Supply
LanguageEnglish

Related product manuals