[:DC]? Takes a measurement; returns the averaged voltage.
:ACDC? Takes a measurement; returns the RMS voltage (AC + DC).
:HIGH? Takes a measurement; returns the High level of a voltage pulse.
:LOW? Takes a measurement; returns the Low level of a voltage pulse.
:MAXimum? Takes a measurement; returns the maximum voltage.
:MINimum? Takes a measurement; returns the minimum voltage.
:ARRAY
:CURRent[:DC]? Takes a measurement; returns the instantaneous current.
:POWer[:DC]? Takes a measurement; returns the instantaneous power.
:VOLTage[:DC]? Takes a measurement; returns the instantaneous voltage.
OUTPut
[:STATe] 0|OFF|1|ON Enables or disables the output.
:COUPle
[:STATe] 0|OFF|1|ON Enables or disables output coupling.
:DOFFset <value> Sets a delay offset to synchronize coupled output state changes.
:MAX
:DOFFset? Returns the delay offset required for this instrument.
:DELay
:FALL <value> Sets the output turn-off sequence delay.
:RISE <value> Sets the output turn-on sequence delay.
:TMODE
:COUPle 0|OFF|1|ON Couples the turn-on and turn-off settings (RP793xA, RP794xA)
[:OFF] LOWZ|HIGHZ Selects the output turn-off mode (RP793xA,RP794xA)
:ON LOWZ|HIGHZ Selects the output turn-on mode (RP793xA, RP794xA)
:INHibit
:MODE LATChing|LIVE|OFF Sets the operating mode of the remote inhibit digital pin.
:PON
:STATe RST|RCL0 Sets the output power-on state.
:PROTection
:CLEar Resets the latched protection.
:TEMPerature
:MARGin? Returns the margin remaining before the over-temperature trips.
:WDOG
[:STATe] 0|OFF|1|ON Enables or disables the I/O watchdog timer.
:DELay <value> Sets the watchdog delay time.
:RELay
:LOCK
[:STATe] 0|OFF|1|ON Enables or disables the locked relay state of the SD1000A unit.
SENSe
:AHOur
:RESet Resets the amp-hour or watt-hour measurement to zero.
:ELOG
Keysight RP7900 Series Operating and Service Guide 27