[:DC]? Takes a measurement; returns the averaged voltage.
:ACDC? Takes a measurement; returns the RMS voltage (AC + DC).
:HIGH? Takes a measurement; returns the High level of a voltage pulse.
:LOW? Takes a measurement; returns the Low level of a voltage pulse.
:MAXimum? Takes a measurement; returns the maximum voltage.
:MINimum? Takes a measurement; returns the minimum voltage.
:ARRAY
:CURRent[:DC]? Takes a measurement; returns the instantaneous current.
:POWer[:DC]? Takes a measurement; returns the instantaneous power.
:VOLTage[:DC]? Takes a measurement; returns the instantaneous voltage.
OUTPut
[:STATe] 0|OFF|1|ON Enables or disables the output.
:COUPle
[:STATe] 0|OFF|1|ON Enables or disables output coupling.
:DOFFset <value> Sets a delay offset to synchronize coupled output state changes.
:MAX
:DOFFset? Returns the delay offset required for this instrument.
:DELay
:FALL <value> Sets the output turn-off sequence delay.
:RISE <value> Sets the output turn-on sequence delay.
:TMODE
:COUPle 0|OFF|1|ON Couples the turn-on and turn-off settings (RP793xA, RP794xA)
[:OFF] LOWZ|HIGHZ Selects the output turn-off mode (RP793xA,RP794xA)
:ON LOWZ|HIGHZ Selects the output turn-on mode (RP793xA, RP794xA)
:INHibit
:MODE LATChing|LIVE|OFF Sets the operating mode of the remote inhibit digital pin.
:PON
:STATe RST|RCL0 Sets the output power-on state.
:PROTection
:CLEar Resets the latched protection.
:TEMPerature
:MARGin? Returns the margin remaining before the over-temperature trips.
:WDOG
[:STATe] 0|OFF|1|ON Enables or disables the I/O watchdog timer.
:DELay <value> Sets the watchdog delay time.
:RELay
:LOCK
[:STATe] 0|OFF|1|ON Enables or disables the locked relay state of the SD1000A unit.
SENSe
:AHOur
:RESet Resets the amp-hour or watt-hour measurement to zero.
:ELOG
Keysight RP7900 Series Operating and Service Guide 27
1 Quick Reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies RP7900 Series and is the answer not in the manual?

Keysight Technologies RP7900 Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelRP7900 Series
CategoryPower Supply
LanguageEnglish

Related product manuals