Getting Started 2
Keysight 34980A Mainframe User’s Guide 51
Wiring a Terminal Block
1 To remove the terminal block cover, insert a screwdriver through the hole in
the cover as shown. Gently push the tab in the direction of the arrow.
2 While pushing the tab (Step 1), lift the clear plastic cover from the edge near
the D-sub connectors. Slide the cover from under the tab holders and remove
the cover.
3 Make connections to the individual terminals as appropriate. Use a suitable
wire type, gauge and insulation for your application (typical is 20 AWG; the
terminals can accommodate a maximum of 18 AWG). Use a 2.5 mm cable tie
as shown for additional strain relief.