Keysight M8194A 120 GSa/s Arbitrary Waveform Generator User Guide 137
Remote Programming 4
Parameters <level>
Parameter Suffix None
Description This command sets or queries the output high level.
Examples Command
:VOLT:HIGH 3e-1
Query
:VOLT:HIGH? -> 3e-1
[:SOURce]:VOLTage[1|4][:LEVel][:IMMediate]:LOW[?]
Command [:SOURce]:VOLTage[1|4][:LEVel][:IMMediate]:LOW
<level>
Query [:SOURce]:VOLTage[1|4][:LEVel][:IMMediate]:LOW?
Parameters <level>
Parameter Suffix None
Description This command sets or queries the output low level.
Examples Command
:VOLT:LOW -0.3
Query
:VOLT:LOW? -> -0.3
[:SOURce]:VOLTage[1|4][:LEVel][:IMMediate]:OFFSet[?]
Command [:SOURce]:VOLTage[1|4][:LEVel][:IMMediate]:OFFSet
<level>
Query [:SOURce]:VOLTage[1|4][:LEVel][:IMMediate]:OFFSet?
Parameters <level>
Parameter Suffix None
Description This command sets or queries the output offset.
Examples Command
:VOLT:OFFS 0.02