Keysight M8194A 120 GSa/s Arbitrary Waveform Generator User Guide 79
M8194A Soft Front Panel 3
Coding/Mod.
This drop-down list selects the different channel coding and
modulation schemes that are supported (see list above). NRZ is the
default selection.
Bit/Signaling Rate
This edition field should be used to enter the signaling speed (or
baud rate) for the modulated signal expressed in Bauds (1 Baud = 1
Symbol/s). Baud rate is equal to the bit rate for two-level line coding
schemes. 4GBaKeysight TechnologiesKeysight Technologiesud is
the default value.
Edge Shape
This drop-down list allows the selection of shape for the transitions
(edges); choices are ‘Rectangular’, ‘Trapezoidal’ (linear), First Order’
(RC network), ‘Gaussian’, ‘Bessel Thompson’ (4th order
Bessel-Thomson reference receiver filter), ‘Raised Cosine’ and ‘Root
Raised Cosine’ (Square Root Raised Cosine).‘
Notes:
The default edge shape is ‘Gaussian’.
For clock signals (i.e. the Clock Toggle button is set to ‘C/2’ or
‘C/4’) the edge shape is always Gaussian.
Thresholds
This drop-down list sets the level threshold convention for the
measure rise/fall time parameters. Choices are b_20_80 (20%-80%)
and b_10_90 (10%-90%). 20%-80% is the default selection for this
control.
Rise Time (UI)
Rise/fall times can be set-up through this edition field. Time must be
expressed in UIs (Unit Interval) as a fraction of the symbol duration.
Rise time can be set up for all the edges shapes except for the
Unfiltered, Raised-Cosine and Square Root of Raised-Cosine
shapes. Rise time is fixed for clock signals to two sample periods in
order to minimize clock jitter. 400mUI (0.4 UI) is the default value for
this field.
Alpha
This edition field only shows up when the Raised Cosine and
Square-root of Raised Cosine edge shapes are selected. With it, the
excess bandwidth parameter (alpha) of the isolated pulses can be
set up. Alpha = 1.0 is the default value.