[SOURce:]ARB:CURRent:STAircase:TIMe <value>, (@<chanlist>)
[SOURce:]ARB:CURRent:STAircase:TIMe? [MIN|MAX,] (@<chanlist>)
[SOURce:]ARB:VOLTage:STAircase:TIMe<value>, (@<chanlist>)
[SOURce:]ARB:VOLTage:STAircase:TIMe? [MIN|MAX,] (@<chanlist>)
[SOURce:]ARB:POWer:STAircase:TIMe<value>, (@<chanlist>)
[SOURce:]ARB:POWer:STAircase:TIMe? [MIN|MAX,] (@<chanlist>)
[SOURce:]ARB:RESISTANCE:STAircase:TIMe<value>, (@<chanlist>)
[SOURce:]ARB:RESISTANCE:STAircase:TIMe? [MIN|MAX,] (@<chanlist>)
Specifies the total time to complete all of the staircase steps in seconds. Each step is of equal time.
[SOURce:]ARB:SEQuence:STEP:CURRent:STAircase:TIMe <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:CURRent:STAircase:TIMe? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:STAircase:TIMe <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:STAircase:TIMe? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:STAircase:TIMe <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:STAircase:TIMe? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:STAircase:TIMe <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:STAircase:TIMe? [MIN|MAX,] <step#>, (@<chanlist>)
Specifies the total time to complete all of the staircase steps in seconds for Arb sequence steps. Each
step is of equal time.
Parameter Typical Return
0 – 262.144 | MIN | MAX, *RST 1 <staircase time>
Step 0 - 99, *RST 0 (none)
Programs a time for the current staircase: ARB:CURR:STA:TIM 10,(@1)
Programs a time for the voltage staircase: ARB:VOLT:STA:TIM 10,(@1)
Programs a time for the power staircase: ARB:POW:STA:TIM 10,(@1)
Programs a time for the resistance staircase: ARB:RESISTANCE:STA:TIM 10,(@1)
Programs a time for step 0:ARB:SEG:STEP:CURR:STA:TIM 10, 0,(@1)
5 SCPI Programming Reference
210 Keysight N6700C Operating and Service Guide