Parameter Typical Return
Current: 0 - maximum|MIN|MAX, *RST MIN
Voltage: 0 - maximum|MIN|MAX, *RST MIN
Power: 0 - maximum|MIN|MAX, *RST MIN
Resistance: 0 - maximum|MIN|MAX, *RST MIN
Values are range and module-rating dependent.
<start value>
Step 0 - 99, *RST 0 (none)
Programs a start level current: ARB:CURR:STA:STAR 1,(@1)
Programs a start level voltage: ARB:VOLT:STA:STAR 10,(@1)
Programs a start level power: ARB:POW:STA:STAR 10,(@1)
Programs a start level resistance: ARB:RESISTANCE:STA:STAR 100,(@1)
Programs an start level for step 0:ARB:SEQ:STEP:CURR:STA:STAR 1, 0,(@1)
[SOURce:]ARB:CURRent:STAircase:STARt:TIMe <value>, (@<chanlist>)
[SOURce:]ARB:CURRent:STAircase:STARt:TIMe? [MIN|MAX,] (@<chanlist>)
[SOURce:]ARB:VOLTage:STAircase:STARt:TIMe<value>, (@<chanlist>)
[SOURce:]ARB:VOLTage:STAircase:STARt:TIMe? [MIN|MAX,] (@<chanlist>)
[SOURce:]ARB:POWer:STAircase:STARt:TIMe<value>, (@<chanlist>)
[SOURce:]ARB:POWer:STAircase:STARt:TIMe? [MIN|MAX,] (@<chanlist>)
[SOURce:]ARB:RESISTANCE:STAircase:STARt:TIMe<value>, (@<chanlist>)
[SOURce:]ARB:RESISTANCE:STAircase:STARt:TIMe? [MIN|MAX,] (@<chanlist>)
Specifies the delay in seconds after the trigger is received, but before the staircase occurs.
[SOURce:]ARB:SEQuence:STEP:CURRent:STAircase:STARt:TIMe <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:CURRent:STAircase:STARt:TIMe? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:STAircase:STARt:TIMe <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:STAircase:STARt:TIMe? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:STAircase:STARt:TIMe <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:STAircase:STARt:TIMe? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:STAircase:STARt:TIMe <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:STAircase:STARt:TIMe? [MIN|MAX,] <step#>, (@<chanlist>)
Specifies the delay in seconds after the trigger is received, but before the staircase occurs for Arb
sequence steps.
Parameter Typical Return
0 262.144 | MIN | MAX, *RST 0 <start time>
Step 0 - 99, *RST 0 (none)
Programs a start time for the current staircase:ARB:CURR:STA:STAR:TIM 1,(@1)
Programs a start time for the voltage staircase:ARB:VOLT:STA:STAR:TIM 1,(@1)
Programs a start time for the power staircase:ARB:POW:STA:STAR:TIM 1,(@1)
Programs a start time for the resistance staircase: ARB:RESISTANCE:STA:STAR:TIM 1,(@1)
Programs a start time for step 0:ARB:SEG:STEP:CURR:STA:STAR:TIM 1, 0,(@1)