[SOURce:]ARB:SEQuence:STEP:CURRent:TRAPezoid:RTIMe <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:CURRent:TRAPezoid:RTIMe? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:TRAPezoid:RTIMe <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:TRAPezoid:RTIMe? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:TRAPezoid:RTIMe <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:TRAPezoid:RTIMe? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:TRAPezoid:RTIMe <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:TRAPezoid:RTIMe? [MIN|MAX,] <step#>, (@<chanlist>)
Specifies the rise time of the trapezoid in seconds for Arb sequence steps.
Parameter Typical Return
0 262.144 | MIN | MAX, *RST 1 <rise time>
Step 0 - 99, *RST 0 (none)
Programs a rise time for the current trapezoid: ARB:CURR:TRAP:RTIM 10,(@1)
Programs a rise time for the voltage trapezoid: ARB:VOLT:TRAP:RTIM 10,(@1)
Programs a rise time for the power trapezoid: ARB:POW:TRAP:RTIM 10,(@1)
Programs a rise time for the resistance trapezoid: ARB:RESISTANCE:TRAP:RTIM 10,(@1)
Programs a rise time for step 0:ARB:SEQ:STEP:CURR:TRAP:RTIM 10, 0,(@1)
[SOURce:]ARB:CURRent:TRAPezoid:STARt[:LEVel] <value>, (@<chanlist>)
[SOURce:]ARB:CURRent:TRAPezoid:STARt[:LEVel]? [MIN|MAX,] (@<chanlist>)
[SOURce:]ARB:VOLTage:TRAPezoid:STARt[:LEVel] <value>, (@<chanlist>)
[SOURce:]ARB:VOLTage:TRAPezoid:STARt[:LEVel]? [MIN|MAX,] (@<chanlist>)
[SOURce:]ARB:POWer:TRAPezoid:STARt[:LEVel] <value>, (@<chanlist>)
[SOURce:]ARB:POWer:TRAPezoid:STARt[:LEVel]? [MIN|MAX,] (@<chanlist>)
[SOURce:]ARB:RESISTANCE:TRAPezoid:STARt[:LEVel] <value>, (@<chanlist>)
[SOURce:]ARB:RESISTANCE:TRAPezoid:STARt[:LEVel]? [MIN|MAX,] (@<chanlist>)
Specifies the initial and final current, voltage, power, or resistance level of the trapezoid.
[SOURce:]ARB:SEQuence:STEP:CURRent:TRAPezoid:STARt[:LEVel] <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:CURRent:TRAPezoid:STARt[:LEVel]? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:TRAPezoid:STARt[:LEVel] <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:TRAPezoid:STARt[:LEVel]? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:TRAPezoid:STARt[:LEVel] <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:TRAPezoid:STARt[:LEVel]? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:TRAPezoid:STARt[:LEVel] <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:TRAPezoid:STARt[:LEVel]? [MIN|MAX,] <step#>, (@<chanlist>)
Specifies the initial and final current, voltage, power, or resistance level of the trapezoid for Arb