EasyManua.ls Logo

Keysight N6702C - Page 268

Keysight N6702C
430 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OUTPut:INHibit:MODE LATChing|LIVE|OFF
OUTPut:INHibit:MODE?
Sets the operating mode of the remote inhibit digital pin. The inhibit function shuts down the output in
response to an external signal on the Inhibit input pin. The Inhibit mode is stored in non-volatile
memory. See Inhibit Input.
LATChing - a logic-true signal on the Inhibit input causes the output state to latch OFF. The output
remains disabled until the Inhibit input is returned to logic-false and the latched INH status bit is
cleared by sending the OUTPut:PROTection:CLEar command or a protection clear command from the
front panel.
LIVE - allows the enabled output to follow the state of the Inhibit input. When the Inhibit input is true,
the output is disabled. When the Inhibit input is false, the output is re-enabled.
OFF - The Inhibit input is ignored.
Parameter Typical Return
LATChing|LIVE|OFF LATC, LIVE, or OFF
Sets the Inhibit input to latching mode: OUTP:INH:MODE LATC
OUTPut:PON:STATe RST|RCL0
OUTPut:PON:STATe?
This determines whether the power-on state is set to the *RST state (RST) or the state stored in
memory location 0 (RCL0). Instrument states can be stored using the *SAV command. This parameter
is saved in non-volatile memory.
Parameter Typical Return
RST|RCL0 RST or RCL0
Sets the power-on state to the *RST state: OUTP:PON:STAT RST
OUTPut:PROTection:CLEar (@<chanlist>)
This clears the latched protection status that disables the output when a protection condition occurs
(see Programming Output Protection). The output is restored to the state it was in before the
protection condition occurred.
Parameter Typical Return
(none) (none)
Clears the latched protection status: OUTP:PROT:CLE (@1)
l All conditions that generate the fault must be removed before the latched status can be cleared.
The output is restored to the state it was in before the fault condition occurred.
5 SCPI Programming Reference
268 Keysight N6700C Operating and Service Guide