l If a protection shutdown occurs during an output list, the list continues running even though the
output is disabled. When the protection status is cleared and the output becomes enabled again,
the output will be set to the values of the step that the list is presently at.
OUTPut:PROTection:COUPle 0|OFF|1|ON
Enables or disables channel coupling for protection faults. When enabled, ALL output channels are
disabled when a protection fault occurs on any output channel. When disabled, only the affected
output channel is disabled when a protection fault is triggered
Parameter Typical Return
0|OFF|1|ON , *RST OFF 0or1
Turns the output coupling protection on: OUTP:PROT:COUPON
OUTPut:PROTection:DELay <value>, (@<chanlist>)
OUTPut:PROTection:DELay? [MIN|MAX,] (@<chanlist>)
This command is the same as [SOURce:]CURRent:PROTection:DELay.
Sets the over-current protection delay. The over-current protection function will not be triggered
during the delay time. After the delay time has expired, the over-current protection function will be
active. This prevents momentary changes in output status from triggering the over-current protection
function. Values up to 255 milliseconds can be programmed with a resolution of 1 millisecond.
Parameter Typical Return
0 - 0.255|MIN|MAX, *RST 0.020 <delay value>
Sets a delay protection of 0.2 seconds: OUTP:PROT:DEL 0.2, (@1)
l The operation of over-current protection is affected by the setting of the current protection delay
start event, which is specified by [SOURce:]CURRent:PROTection:DELay:STARt.
OUTPut:PROTection:OSCillation 0|OFF|1|ON, (@<chanlist>)
OUTPut:PROTection:OSCillation? (@<chanlist>)
Enables/Disables oscillation protection. If capacitive loads cause the output to oscillate on any of the
bandwidth settings, this protection function will detect the oscillation and latch the output off.
Parameter Typical Return
0|OFF|1|ON, *RST OFF 0or1
Enables oscillation protection: OUTP:PROT:OSC ON, (@1)