:PASSword
:FPANel
:RESet Resets the front panel lockout password to zero.
:PERSona
:MANufacturer “<manufacturer> Changes the manufacturer identity.
:DEFault Sets the manufacturer identity to the factory default.
:MODel “<model number> Changes the model number.
:DEFault Sets the model number to the factory default.
:REBoot Reboots the instrument to its power-on state.
:SECurity
:IMMediate Clears all user memory and reboots the instrument.
:VERSion? Returns the SCPI version that the instrument complies with.
TRIGger (ACQuire and ELOG commands only on N676xA, N678xA SMU, Option 054)
:ACQuire
[:IMMediate] (@chanlist) Generates an immediate measurement trigger.
:CURRent
[:LEVel] <value>, (@chanlist) Sets the triggered level of the output.
:SLOPe POSitive|NEGative, (@chanlist) Sets the slope of the signal.
:SOURce <source>, (@chanlist) Selects the trigger source for the acquisition system: BUS |CURRent<1-4>
|EXTernal |PIN<1-7> |TRANsient<1-4> |VOLTage<1-4>
:TOUTput
[:ENABle] 0|OFF|1|ON, (@chanlist) Enables measurement triggers to be sent to a digital port pin.
:VOLTage
[:LEVel] <value>, (@chanlist) Sets the triggered level of the output.
:SLOPe POSitive|NEGative, (@chanlist) Sets the slope of the signal.
:ARB
:SOURce <source> Selects the trigger source for the arbitrary waveform generator:
BUS |EXTernal |IMMediate
:ELOG
[:IMMediate] (@chanlist) Generates an immediate trigger for external data logging.
:SOURce <source>, (@chanlist) Selects the trigger source for external data logging:
BUS |EXTernal |IMMediate| PIN<1-7>
:MEASure
:TALign
:CORRection
[:STATe] 0|OFF|1|ON Improves the alignment of measurement triggers with measurement data.
:TRANsient
[:IMMediate] (@chanlist) Generates an immediate output transient trigger.
:SOURce <source>, (@chanlist) Selects the trigger source for the transient system:
BUS |EXTernal IMMediate |PIN<1-7> |TRANsient<1-4>
Keysight N6700C Operating and Service Guide 39