3 VMA Mode
3.1 Digital Demod Measurement
State Saved Yes
Backwards
Compatibility
SCPI
[:SENSe]:DDEMod:MIMO:IPADdress1|2:LOCKed
Channel Configuration Information (Remote Query only)
Reads back channel configuration information.
Remote Command
[:SENSe]:DDEMod:MCHannel:CHANnel:INFO?
Example
:DDEM:MCH:CHAN:INFO?
Backwards Compatibility
SCPI
[:SENSe]:DDEMod:MIMO:CHANnel:INFO
3.1.9.8 BER
Enables you to set Tx BER parameters.
BER
Turns Tx BER on or off. When Tx BER is on, the results of BER, Error Bits, and Total
Bits are displayed in Demod Bits window.
NOTE
When segment2 is enabled, Tx BER measurement will be only performed on
segment2.
Remote
Command
[:SENSe]:DDEMod:SEGMent1|…|6:BER:STATe OFF | ON | 0 | 1
[:SENSe]:DDEMod:SEGMent1|…|6:BER:STATe?
Example
:DDEM:SEGM1:BER:STAT ON
:DDEM:SEGM1:BER:STAT?
Couplings Available only when Tx Pattern has been recalled
Preset
OFF
State Saved Yes
Backwards
Compatibility
SCPI
[:SENSe]:DDEMod:BER:STATe
373 Vector Modulation Analyzer Mode User's &Programmer's Reference