A-61560 April 2008 113
5. Replace the core assembly in the feed module. You may need to
slide the shaft to the right or left so the core fits properly within the
feed module housing.
6. Repeat the replacement procedure outlined above for the other core
assembly.
7. Reinstall the feed module.
8. Reinstall the feed module cover by aligning the tabs in the slots and
pushing the feed module cover down until it snaps into place.
Vacuuming the scanner Before cleaning the imaging area, it is suggested that you vacuum the
inside of the scanner to remove any dust and debris.
Cleaning the imaging area 1. Remove dust and debris from this area by using a Staticide wipe. Be
careful not to scratch the imaging area when cleaning.
IMPORTANT: Staticide wipes contain isopropanol which can cause eye
irritation and dry skin. Wash your hands with soap and
water after performing maintenance procedures. Refer to
the MSDS for more information.
2. Wipe the upper and lower imaging area again using the reusable
optics cleaner pad to remove any streaks. The optics lamps will stay
on to allow detailed cleaning and viewing of the optics glass flats.
3. When finished, close the scanner cover.
Slide shaft