EasyManua.ls Logo

KRAL KV - 11 Maintenance; 11.1 Dangers during maintenance; 11.2 Required maintenance; 11.4 Maintaining the pump

Default Icon
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11 Maintenance
11.1 Dangers during maintenance
11 Maintenance
11.1 Dangers during maintenance
The following safety instructions must be observed strictly:
o Have all work carried out only by authorized qualified personnel.
o Before beginning work, let the pump unit cool down slowly to the ambient temperature. Avoid
rapid temperature changes.
o Pumped liquids can be hot, poisonous, combustible and caustic. Use corresponding protective
equipment.
o Collect any discharging pumped liquid safely and dispose of it in an environmentally compatible
manner in accordance with the applicable local regulations.
o Ensure that the collection tank for discharging pumped liquids is sufficiently large.
o Observe the operating instructions and data sheets of the components.
11.2 Required maintenance
The service life depends on the observance of the operating conditions of the pump and the require-
ments from the operating instructions of the components.
Component Required maintenance Cycle
Pump
o Visual inspection
o Acoustic inspection
4weeks
Filter/strainer (system side)
o Check of the suction-side
pressure
2weeks
Magnetic coupling
o Check of the tightening
torques
1year
Overflow valve
o Function test
≤5years
Tab.9: Required maintenance
11.3 Ball bearing
When using the pump in lubrication oil applications with a minimum purity class of 21/18/13 according
to ISO4406, a bearings replacement at the latest after 5 years (400000h) is sufficient.
11.4 Maintaining the pump
Personnel qualification: o Fitter
Personal protective equipment: o Work clothing
o Protective gloves
o Safety boots
o Face protection
DANGER
Magnetic field.
Risk of death for persons with cardiac pacemaker, metallic implant or neurostimulator.
Under no circumstances may persons with cardiac pacemakers, metallic implant or
neurostimulator perform work on the pump/pump unit.
WARNING
Risk of injury through emitted pumped liquid.
Pumped liquids can be hot, poisonous, combustible and caustic.
Wear personal protective clothing during all the work. Ensure face protection.
Collect any discharging pumped liquid safely and dispose of it in an environmentally compatible
manner in accordance with the applicable local regulations.
28
OIK 09en-GB Edition 2019-11
Operating instructions

Table of Contents

Related product manuals