15 Accessories
15.1 Heating
Installing the fluid heating system
Personnel qualification: o Fitter
Personal protective equipment: o Work clothing
o Protective gloves
o Safety boots
DANGER
Magnetic field.
Risk of death for persons with cardiac pacemaker, metallic implant or neurostimulator.
► Under no circumstances may persons with cardiac pacemakers, metallic implant or neurostimu-
lator perform work on the pump/pump unit.
072 Heating cover
1 Pipe connection
1. Remove the socket screws and rating plate at the end cover of the pump.
2. Mount the heating cover072 to the end cover using the supplied socket screws.
3. Mount the piping at the pipe connections1.
4. Mount the rating plate on the heating cover.
Commissioning the fluid heating system
DANGER
Magnetic field.
Risk of death for persons with cardiac pacemaker, metallic implant or neurostimulator.
► Under no circumstances may persons with cardiac pacemakers, metallic implant or neurostimu-
lator perform work on the pump/pump unit.
DANGER
Risk of injury through emitted pumped liquid.
The pump housing may burst through heat expansion of the pumped liquid.
► Open all the valves during the heating process.
1. Take the required heating-up periods into account Ä Accessories,Page40.
2. When setting the pressure and temperature of the heating fluid take the permissible operating
limits of the pump into account Ä Technical data,Page8.
15.1.4 Heating system special design
Please contact the manufacturer for special designs.