15 Accessories
15.1 Heating
Commissioning the electrical heating system
DANGER
Magnetic field.
Risk of death for persons with cardiac pacemaker, metallic implant or neurostimulator.
Under no circumstances may persons with cardiac pacemakers, metallic implant or
neurostimulator perform work on the pump/pump unit.
DANGER
Risk of injury through emitted pumped liquid.
The pump housing may burst through heat expansion of the pumped liquid.
Open all the valves during the heating process.
1. Switch on the electric heating system.
2. Take the required heating-up periods into account Ä Accessories,Page40.
15.1.3 Fluid heating system
072
11
Fig.13: Fluid heating system
072 Heating cover
1 Pipe connection
The fluid heating system consists of a heating cover 072 attached additionally to the end cover through
which a heating fluid (for example vapour, thermal oil) flows.
Scope of delivery:
Size K 5–2900
1 heating cover
4 socket screws
Tab.16: Scope of delivery of the fluid heating system
Heating liquid operating data
Parameter Unit Value
Max. operating overpressure [bar] 16
Max. temperature [°C] 200
Tab.17: Heating liquid operating data
Heating-up period
Required heating-up period for the temperature difference of 50°C at a liquid temperature of 200°C:
Size Heating-up period [min] at a temperature difference of 50°C
5–118 20
160–275 45
370–450 60
550–660 90
851–1301 120
1500–1700 150
2200–2900 180
Tab.18: Heating-up period for fluid heating system