Kramer Electronics Ltd.
VP-440 Protocol 3000
54
NET-DHCP
Functions
Permission
Transparency
Set:
NET-DHCP
Administrator
-
Get:
NET-DHCP?
End User
-
Description
Syntax
Set:
Set DHCP mode
#NET-DHCPP1
Get:
Get DHCP mode
#NET-DHCP?
Response
Set: ~nn@NET-DHCPP1OK␍␊
Get: ~nn@NET-DHCPmode␍␊
Parameters
P1 0=Static IP; 1=DHCP
0 Use static IP.
1 Use DHCP. If unavailable, use IP as above.
Notes
Connecting Ethernet to devices with DHCP may take more time in some networks.
To connect with a randomly assigned IP by DHCP, specify the device DNS name (if available) using the
command “NAME”. You can also get an assigned IP by direct connection to USB or RS-232 protocol port
if available.
For proper settings consult your network administrator.
NET-GATE
Functions
Permission
Transparency
Set:
NET-GATE
Administrator
-
Get:
NET-GATE?
End User
-
Description
Syntax
Set:
Set Gateway IP
#NET-GATEP1
Get:
Get Gateway IP
#NET-GATE?
Response
Set: ~nn@NET-GATEP1OK␍␊
Get: ~nn@NET-GATEip_address␍␊
Parameters
P1 (valid IP address)=xxx.xxx.xxx.xxx
Notes
A network gateway connects the device via another network and maybe over the Internet. Be careful of
security problems. For proper settings consult your network administrator