EasyManua.ls Logo

Kramer VP-440

Kramer VP-440
65 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Kramer Electronics Ltd.
VP-440 – Technical Specifications
40
Default Communication Parameters
RS-232
Baud Rate:
9,600
Data Bits:
8
Stop Bits:
1
Parity:
None
Ethernet
IP Address:
192.168.1.39
Subnet mask:
255.255.0.0
Default gateway:
0.0.0.0
Default UDP Port #:
50000
Maximum UDP Ports:
4
Max. # of concurrently connected clients
4
Full Factory Reset
OSD
Go to: Menu-> Factory-> RESET->Change the option to YES
and press Enter
Protocol 3000 Command
See FACTORY on page 49
Web Pages (Soft Factory Reset)
1. Go to Device Settings (see Configuring Network
Settings on page 25).
2. Click Soft Factory Reset.
IP address values and User/Password settings do not return
to their factory default parameters.
RS-232/Ethernet (UDP) Command Protocol
Command Format:
ASCII protocol 3000
Example (Route the video HDMI3 input
to the output):
#ROUTE 12,1,2<cr>