EasyManua.ls Logo

Kramer VP-773A - Page 108

Kramer VP-773A
119 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
102
VP-773A - The VP-773A RS-232 Communication Protocol
1st
Level
2nd Level
3rd Level
4th Level
Range
Func.
Note
Group B
None
0 (read only)
292
Activate CH1
1
Activate CH2
2
Bypass
3
Group C
None
0 (read only)
293
Activate CH1
1
Activate CH2
2
Bypass
3
Group D
None
0 (read only)
294
Activate CH1
1
Activate CH2
2
Bypass
3
Bypassed Group
Unmute
0
295
Mute
1
Process
Deinterlacing
Method
Line Doubler
0
311
Volatile parameter
unavailable in
progressive scan
Motion Adaptive
1
Sync
Current Field
0
312
Unavailable in
progressive scan.
Older Field
1
Film Mode
Off
0
320
Unavailable in
progressive scan
Follow Input
1
24PsF Mode
2
Diagonal
Correction
0:3
330
Unavailable in
progressive scan.
Unavailable when
deinterlacing sync is
older field
MD Sensitivity
LEVEL1
0
340
Unavailable in
progressive scan
LEVEL2
1
LEVEL3
2
LEVEL4
3
LEVEL5
4
Picture
Brightness
-400:400
410
In the OSD menu
the range appears
as -80:80
Contrast
0.1:1.6
420
Color
0.1:1.6
430
Color
Correction
Blue
0:4
441
Green
0:4
442
Flesh
0:4
443
Black Level
-80:80
450
Gamma Mode
Gamma Off
0
460
Gamma 0.4
1
Gamma 0.8
2
Gamma 1.2
3
Gamma 1.6
4
Gamma 2.0
5
Gamma 2.4
6
Gamma 2.8
7
Dither
Mode0: Disable error diffusion
0
470