108
VP-773A - The VP-773A RS-232 Communication Protocol
13.4 The Protocol 3000 Common Operation Commands
The following table lists the protocol 3000 commands:
Operation Commands
Command
Syntax
Response
Lock front panel
LOCK-FP LOCK-MODE
LOCK-FP LOCK-MODE
RESULT
Get front panel
locking state
LOCK-FP?
LOCK-FP LOCK-MODE
Parameters Description:
LOCK-MODE = Front panel locking state:
"0" or "off" to unlock front panel buttons.
"1" or "on" to lock front panel buttons.
Power state
POWER POWER-MODE
POWER POWER-MODE
RESULT
Get power state
POWER?
POWER POWER-MODE
Parameters Description:
POWER-MODE = power state:
"0" or "off" to enter standby mode.
"1" or "on" to power up.
Restart device
RESET
RESET OK
Peripheral firmware
update execute*
UPGRADE
UPGRADE OK
Usually the firmware will upload to the device via a command such as LDFW
A device reset may be needed to complete the process
Video core Firmware
update execute*
UPGRADES
UPGRADES OK
Reset configuration
to factory default
(including Ethernet
reset)
FACTORY
FACTORY RESULT
Reset Ethernet
configuration to
factory default
ETH-FACTORY
ETH-FACTORY RESULT
SET dedicated EAS
port settings
EAS-CFG PORTTYPE,
PORTNUM
EAS-CFG PORTTYPE,
PORTNUM RESULT
GET dedicated EAS
port settings
EAS-CFG?
EAS-CFG PORTTYPE,
PORTNUM
Parameters Description:
PORTTYPE either “TCP” or “UDP”
PORTNUM Ethernet port
EAS Activation Mode
notification
messages
N/A
EAS-EXE ACTIVATION-MODE OK
Parameters Description:
ACTIVATION-MODE = EAS notification:
1” to notify full screen + siren alert mode (Severity = Extreme)
“2” to notify full screen alert mode (Severity = Severe)
“3” To notify full screen alert mode (Severity = Moderate)