VP-773A - Using the Embedded Web Pages
When Scan mode is activated, the system scans the inputs from the highest to the
lowest priority in search of a valid input signal for each the Main and PiP windows.
The priority is ordered from the lowest input number (8) to the highest (1). For
example, if PC 1 and HDMI 2 have a valid signal and auto switching is enabled, the
VP-773A will scan through the inputs and select the HDMI 2 which is higher in the
priority list (see Figure 45). Once the signal is no longer valid on HDMI 2, the
VP-773A will scan for the next highest-priority valid signal.
Note that you can Check/uncheck the box next to an input to include/exclude it from
the input scan list.
You can change the priority order as well by dragging an input button and dropping
it in a new location, as illustrated in the example in Figure 47. In this example, CV is
moved up in the priority list to be scanned for a valid input after HDMI 1.
Figure 47: The Routing & Scaling Page Auto Switching Window
9.1.4 The Lower Buttons Bar
The lower buttons bar lets you perform quick and easy setups:
Figure 48: The Routing & Scaling Page Lower Buttons Bar