76
Function
Description
Syntax
Parameters/Attributes
Example
MODEL?
Get device model.
This command
identifies equipment
connected to
VS-211XS and
notifies of identity
changes to the
connected
equipment. The
Matrix saves this
data in memory to
answer REMOTE-
INFO requests.
COMMAND
#MODEL?<CR>
FEEDBACK
~nn@MODELmodel_name<CR><LF>
model_name String of up to 19
printable ASCII chars
Get the device
model:
#MODEL?<CR>
MUTE
Set audio mute.
COMMAND
#MUTEout_index,mute_mode<CR>
FEEDBACK
~nn@MUTEout_index,mute_mode<CR><LF>
out_index 1
mute_mode On/Off
0 Off
1 On
Set Output 1 to mute:
#MUTE1,1<CR>
MUTE?
Set audio mute.
COMMAND
#MUTEout_index<CR>
FEEDBACK
~nn@MUTEout_index,mute_mode<CR><LF>
out_index 1
mute_mode On/Off
0 Off
1 On
Get Output 1 to mute:
#MUTE1,1<CR>
NAME
Set machine (DNS)
name.
The machine
name is not the
same as the model
name. The machine
name is used to
identify a specific
machine or a
network in use (with
DNS feature on).
COMMAND
#NAMEmachine_name<CR>
FEEDBACK
~nn@NAMEmachine_name<CR><LF>
machine_name String of up to 15
alpha-numeric chars (can include
hyphen, not at the beginning or end)
Set the DNS name of
the device to room-
442:
#NAMEroom-
442<CR>
NAME?
Get machine (DNS)
name.
The machine
name is not the
same as the model
name. The machine
name is used to
identify a specific
machine or a
network in use (with
DNS feature on).
COMMAND
#NAME?<CR>
FEEDBACK
~nn@NAMEmachine_name<CR><LF>
machine_name String of up to 15
alpha-numeric chars (can include
hyphen, not at the beginning or end)
Get the DNS name of
the device:
#NAME?<CR>
NAME-RST
Reset machine
(DNS) name to
factory default.
Factory default of
machine (DNS)
name is “KRAMER_”
+ 4 last digits of
device serial
number.
COMMAND
#NAME-RST<CR>
FEEDBACK
~nn@NAME-RSTok<CR><LF>
Reset the machine
name (S/N last digits
are 0102):
#NAME-
RSTkramer_0102<
CR>
NET-CONFIG
Set a network
configuration.
Parameters
[DNS1] and
[DNS2]are optional.
For Backward
compatibility, the id
parameter can be
omitted. In this case,
the Network ID, by
default, is 0, which is
the Ethernet control
port.
If the gateway
address is not
compliant to the
subnet mask used
for the host IP, the
command will return
an error. Subnet and
gateway compliancy
specified by
RFC950.
COMMAND
#NET-CONFIGnetw_id,net_ip,net_mask,gateway,[dns1],[dns2]
<CR>
FEEDBACK
~nn@NET-CONFIGnetw_id,net_ip,net_mask,gateway<CR><LF>
netw_id 0
net_ip Network IP
net_mask Network mask
gateway Network gateway
Set the device
network parameters
to IP address
192.168.113.10, net
mask 255.255.0.0,
and gateway
192.168.0.1:
#NET-CONFIG0,19
2.168.113.10,255
.255.0.0,192.168
.0.1<CR>